Alat shutdown gancang séri YCRS tiasa mareuman hiji atanapi dua modul senar maksimal, kalayan arus sirkuit maksimum 55A sareng tegangan sirkuit maksimum 1500VDC. Dijieunna tina bahan PC + ABS sareng gaduh rating panyalindungan IP66. Sababaraha jinis antarmuka sayogi, kalebet liang push-through, panutup tekanan, sareng terminal MC4. Saklar isolasi internal ieu Certified ku TUV.CE.CB.SAA, sarta alat kasebut dilengkepan desain klep waterproof na ventilated pikeun nyegah condesation jero housing.An sensor suhu canggih dipaké pikeun ngadeteksi suhu pangluhurna di jero perumahan nyata. -waktos, sarta switch bakal otomatis neukteuk off lamun hawa internal ngaleuwihan 70 darajat Celsius. Alat ieu cocog pikeun sistem photovoltaic padumukan, industri, sareng komérsial.
Kontak Kami
Naha sistem pembangkit listrik photovoltaic kudu dilengkepan alat shutdown gancang? Pamakéan alat shutdown gancang dina sistem photovoltaic (PV) geus jadi beuki penting alatan YCRS Rapid Shutdown Device YCRS Rapid Shutdown Deviceka masalah kaamanan dina taun panganyarna. Kacilakaan sistem PV sering nyababkeun kahuruan, sareng 80% tina kahuruan ieu disababkeun ku arcing tegangan DC. Salaku tambahan, kusabab seueur sistem PV anu disebarkeun dipasang di daérah anu padat penduduk atanapi caket fasilitas industri, kacilakaan atanapi kagagalan tiasa nyababkeun karugian anu signifikan tina kahirupan sareng harta. Ku alatan éta, loba nagara merlukeun yén sistem PV dilengkepan alat shutdown gancang-tingkat komponén guna ngaleungitkeun tegangan DC dina kaayaan darurat tur ngajaga kasalametan tanaga firefighting jeung pangropéa, kitu ogé pikeun mastikeun kasalametan sakabéh sistem. Upami aya seuneu atanapi darurat anu sanés, tanaga pangropéa tiasa gancang-gancang megatkeun sambungan unggal komponén ku cara nutup alat YCRS sareng ngaleungitkeun tegangan DC, sahingga ngajaga kasalametan tanaga pemadam kebakaran sareng perawatan.
YCRS | — | 50 | 2 | MC4 |
Kode perusahaan | Dipeunteun ayeuna | Modeu kabel | Jenis gabungan | |
switch kaamanan firefighter | 13:13A 20: 20A 25: 25A 40:40A 50: 50A | 2: 2P 4: 4P 4b: 4b 6: 6P 8: 8p 10: 10P 12:12P 14:14P 16:16P 18:18P 20: 20P | MC4: MC4 gabungan /: No |
Catetan: RP Rapid Shutdown Pindah / Panel
Modél | YCRS-2/4P/4B | YCRS-6/8 | YCRS-10 | YCRS-12~20 Gede |
tegangan string (VDC) | 300~1500 | 300~1500 | 300~1500 | 300~1500 |
Arus string A | 9~55 | 9~55 | 9~55 | 9~55 |
Sirkuit mulang | 1/2 | 3/4/5 | 3/4/5 | 6/8/10 |
Métode sambungan circuit switch isolasi | 2/4/4B | 6/8 | 10 | 12/16/20 |
tegangan gawé | 100Vac-270Vac | 100Vac-270Vac | 100Vac-270Vac | 100Vac-270Vac |
tegangan dipeunteun | 230Vac | 230Vac | 230Vac | 230Vac |
Dipeunteun ayeuna | 30mA | 30mA | 30mA | 60mA |
Mimitian (loading) ayeuna | 100mA (AVG) | 100mA (AVG) | 100mA (AVG) | 200mA (AVG) |
Aksi ayeuna | 300mA (Max) | 300mA (Max) | 300mA (Max) | 600mA (Max) |
Kaayaan tindakan kontak | 24Vdc-300mA (Max) | 24Vdc-300mA (Max) | 24Vdc-300mA (Max) | 24Vdc-300mA (Max) |
Suhu gawé | -20 ℃ - + 50 ℃ | -20 ℃ - + 50 ℃ | -20 ℃ - + 50 ℃ | -20 ℃ - + 50 ℃ |
Suhu maksimum saméméh shutdown otomatis | +70 ℃ | +70 ℃ | +70 ℃ | +70 ℃ |
Suhu neundeun | -40 ℃ - + 85 ℃ | -40 ℃ - + 85 ℃ | -40 ℃ - + 85 ℃ | -40 ℃ - + 85 ℃ |
Gelar panyalindungan | IP66 | IP66 | IP66 | IP66 |
panyalindungan overcurrent | II | II | II | II |
Auténtikasi | CE | CE | CE | CE |
Standar | EN60947-1&3 | EN60947-1&3 | EN60947-1&3 | EN60947-1&3 |
Kahirupan mékanis | 10000 | 10000 | 10000 | 10000 |
Operan beban (PV1) | > 1500 | > 1500 | > 1500 | > 1500 |
Data ERS ngarujuk kana isolator DC anu diwangun. Data nurutkeun IEC60947-3 (ed.3.2): 2015, UL508i.Utilization kategori DC-PV1. | Nomer kutub | Sirkuit | Modél | ||||
600V | 800V | 1000V | 1200V | 1500V | |||
32 | 26 | 13 | 10 | 5 | 2 | 1 | YCRS-13 2 |
40 | 30 | 20 | 12 | 6 | 2 | 1 | YCRS-20 2 |
55 | 40 | 25 | 15 | 8 | 2 | 1 | YCRS-25 2 |
/ | 50 | 40 | 30 | 20 | 2 | 1 | YCRS-40 2 |
/ | 55 | 50 | 40 | 30 | 2 | 1 | YCRS-50 2 |
32 | 26 | 13 | 10 | 5 | 4 | 2 | YCRS-13 4 |
40 | 30 | 20 | 12 | 6 | 4 | 2 | YCRS-20 4 |
55 | 40 | 25 | 15 | 8 | 4 | 2 | YCRS-25 4 |
/ | 50 | 40 | 30 | 20 | 4 | 2 | YCRS-40 4 |
/ | 55 | 50 | 40 | 30 | 4 | 2 | YCRS-50 4 |
32 | 26 | 13 | 10 | 5 | 4 | 1 | YCRS-13 4B |
40 | 40 | 40 | 30 | 20 | 4 | 1 | YCRS-20 4B |
/ | / | 55 | 40 | 30 | 4 | 1 | YCRS-25 4B |
/ | / | / | / | 45 | 4 | 1 | YCRS-40 4B |
/ | / | / | / | 50 | 4 | 1 | YCRS-50 4B |
32 | 26 | 13 | 10 | 5 | 6 | 3 | YCRS-13 6 |
40 | 30 | 20 | 12 | 6 | 6 | 3 | YCRS-20 6 |
55 | 45 | 25 | 15 | 8 | 6 | 3 | YCRS-25 6 |
/ | 50 | 40 | 30 | 20 | 6 | 3 | YCRS-40 6 |
/ | 55 | 50 | 40 | 30 | 6 | 3 | YCRS-50 6 |
32 | 26 | 13 | 10 | 5 | 8 | 4 | YCRS-13 8 |
40 | 30 | 20 | 12 | 6 | 8 | 4 | YCRS-20 8 |
55 | 40 | 25 | 15 | 8 | 8 | 4 | YCRS-25 8 |
/ | 50 | 40 | 30 | 20 | 8 | 4 | YCRS-40 8 |
/ | 55 | 50 | 40 | 30 | 8 | 4 | YCRS-50 8 |
32 | 26 | 13 | 10 | 5 | 10 | 5 | YCRS-13 10 |
40 | 30 | 20 | 12 | 6 | 10 | 5 | YCRS-20 10 |
55 | 40 | 25 | 15 | 8 | 10 | 5 | YCRS-25 10 |
/ | 50 | 40 | 30 | 20 | 10 | 5 | YCRS-40 10 |
/ | 55 | 50 | 40 | 30 | 10 | 5 | YCRS-50 10 |
32 | 26 | 13 | 10 | 5 | 12 | 6 | YCRS-13 12 |
40 | 30 | 20 | 12 | 6 | 12 | 6 | YCRS-20 12 |
55 | 40 | 25 | 15 | 8 | 12 | 6 | YCRS-25 12 |
/ | 50 | 40 | 30 | 20 | 12 | 6 | YCRS-40 12 |
/ | 55 | 50 | 40 | 30 | 12 | 6 | YCRS-50 12 |
32 | 26 | 13 | 10 | 5 | 14 | 6 | YCRS-13 14 |
40 | 30 | 20 | 12 | 6 | 14 | 6 | YCRS-20 14 |
55 | 40 | 25 | 15 | 8 | 14 | 6 | YCRS-25 14 |
/ | 50 | 40 | 30 | 20 | 14 | 6 | YCRS-40 14 |
/ | 55 | 50 | 40 | 30 | 14 | 6 | YCRS-50 14 |
Catetan: RP Rapid Shutdown Pindah / Panel
Data ERS ngarujuk kana isolator DC anu diwangun. Data nurutkeun IEC60947-3 (ed.3.2): 2015, UL508i.Utilization kategori DC-PV1. | Nomer kutub | Sirkuit | Modél | ||||
600V | 800V | 1000V | 1200V | 1500V | |||
32 | 26 | 13 | 10 | 5 | 16 | 8 | YCRS-13 16 |
40 | 30 | 20 | 12 | 6 | 16 | 8 | YCRS-20 16 |
55 | 40 | 25 | 15 | 8 | 16 | 8 | YCRS-25 16 |
/ | 50 | 40 | 30 | 20 | 16 | 8 | YCRS-40 16 |
/ | 55 | 50 | 40 | 30 | 16 | 8 | YCRS-50 16 |
32 | 26 | 13 | 10 | 5 | 18 | 8 | YCRS-13 18 |
40 | 30 | 20 | 12 | 6 | 18 | 8 | YCRS-20 18 |
55 | 40 | 25 | 15 | 8 | 18 | 8 | YCRS-25 18 |
/ | 50 | 40 | 30 | 20 | 18 | 8 | YCRS-40 18 |
/ | 55 | 50 | 40 | 30 | 18 | 8 | YCRS-50 18 |
32 | 26 | 13 | 10 | 5 | 20 | 10 | YCRS-13 20 |
40 | 30 | 20 | 12 | 6 | 20 | 10 | YCRS-20 20 |
55 | 40 | 25 | 15 | 8 | 20 | 10 | YCRS-25 20 |
/ | 50 | 40 | 30 | 20 | 20 | 10 | YCRS-40 20 |
/ | 55 | 50 | 40 | 30 | 20 | 10 | YCRS-50 20 |
Catetan: RP Rapid Shutdown Pindah / Panel
runtuyan YCRS-2 / 4P / 4B
runtuyan YCRS-2 / 4P / 4B
runtuyan YCRS-10
YCRS-12~20 runtuyan
2P/4P
6P
8P
10P
12~20P
Catetan: saklar kaamanan seuneu teu tiasa dipasang di tempat anu sinar panonpoé langsung, sareng visor panonpoé disarankeun.