Tinjauan produk
Rincian produk
Ngundeur Data
Produk patali
Umum
Tegangan operasi dipeunteun tina YCB8-63PV runtuyan DC breakers circuit miniatur bisa ngahontal DC1000V, sarta dipeunteun ayeuna operasi bisa ngahontal 63A, nu dipaké pikeun isolasi, overload jeung perlindungan circuit pondok. Hal ieu loba dipaké dina photovoltaic, industri, sipil, komunikasi jeung sistem lianna, sarta ogé bisa dipaké dina sistem DC pikeun mastikeun operasi dipercaya tina sistem DC. Standar: IEC / EN 60947-2, syarat panyalindungan lingkungan EU ROHS.
Kontak Kami
● Desain modular, ukuranana leutik;
● Standar Din rail instalasi, instalasi merenah;
● Overload, sirkuit pondok, fungsi panyalindungan isolasi, panyalindungan komprehensif;
● Ayeuna nepi ka 63A, 14 pilihan;
● The megatkeun kapasitas ngahontal 6KA, kalawan kapasitas panyalindungan kuat;
● asesoris lengkep jeung expansibility kuat;
● Sababaraha métode wiring pikeun minuhan rupa kaperluan wiring konsumén;
● The hirup listrik ngahontal 10000 kali, nu cocog pikeun 25 taun siklus kahirupan photovoltaic.
YCB8 | - | 63 | PV | 4P | C | 20 | DC250 | + | YCB8-63 OF |
Modél | Shell kelas ayeuna | Pamakéan | Jumlah kutub | Ngajanteng | Dipeunteun ayeuna | tegangan dipeunteun | Asesoris | ||
ciri | YCB8-63 OF: bantu | ||||||||
Miniatur sirkuit pameget | 63 | PV: heteropolarity Pvn: nonpolaritas | 1P | BCK | 1A, 2A, 3A….63A | DC250V | YCB8-63 SD: alarem | ||
2P | DC500V | YCB8-63 MX: sékrési Shunt | |||||||
3P | DC750V | ||||||||
4P | DC1000V |
Catetan: Tegangan dipeunteun dipangaruhan ku jumlah kutub sareng mode kabel.
The single poleis DC250V, dua kutub dina runtuyan anu DC500V, jeung saterusna.
Standar | IEC / EN 60947-2 | ||||
Jumlah kutub | 1P | 2P | 3P | 4P | |
Dipeunteun ayeuna kelas pigura cangkang | 63 | ||||
kinerja listrik | |||||
Tegangan kerja dipeunteun Ue (V DC) | 250 | 500 | 750 | 1000 | |
Dipeunteun ayeuna Dina (A) | 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 | ||||
Tegangan insulasi dipeunteun Ui (V DC) | 1200 | ||||
Tegangan impuls dipeunteun Uimp (KV) | 4 | ||||
Kapasitas pegatna pamungkas Icu(KA)(T=4ms) | Pv: 6 PVn: | ||||
Kapasitas Pegatna Operasi ICs (KA) | Ics=100%Icu | ||||
Jenis kurva | Tipe B, Tipe C, Tipe K | ||||
Jenis tripping | Térmomagnétik | ||||
Kahirupan jasa (waktos) | Mékanis | 20000 | |||
Listrik | PV: 1500 PVn: 300 | ||||
Polaritasna | Hétéropolaritas | ||||
Métode inline | Bisa luhur jeung ka handap kana garis | ||||
Asesoris listrik | |||||
Kontak bantu | □ | ||||
Kontak alarm | □ | ||||
Kaluaran shunt | □ | ||||
kaayaan lingkungan lumaku jeung instalasi | |||||
Suhu gawé (℃) | -35~+70 | ||||
Suhu neundeun (℃) | -40~+85 | ||||
résistansi Uap | Kategori 2 | ||||
Jangkungna (m) | Paké kalawan derating luhur 2000m | ||||
Gelar polusi | Tingkat 3 | ||||
Gelar panyalindungan | IP20 | ||||
lingkungan instalasi | Tempat tanpa geter sareng dampak anu signifikan | ||||
Kategori instalasi | Golongan II, Golongan III | ||||
Métode pamasangan | DIN35 rel baku | ||||
Kapasitas wiring | 2.5-25mm² | ||||
torsi terminal | 3,5N·m |
■ Standar □ Pilihan ─ No
Jenis grounding | Sistim grounding hiji-tahap | Sistim Ungrounded | ||
Diagram sirkuit | ||||
Pangaruh kasalahan | Kasalahan A | Maksimum arus pondok-circuit ISC | Kasalahan A | Taya pangaruh |
Kasalahan B | Maksimum arus pondok-circuit ISC | Kasalahan B | Maksimum arus pondok-circuit ISC | |
Kasalahan C | Taya pangaruh | Kasalahan C | Taya pangaruh |
Nilai koreksi ayeuna dipaké dina lingkungan béda
Lingkungan suhu (℃) | -35 | -30 | -20 | -10 | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 |
ayeuna nilai koreksi (A) | ||||||||||||
Dipeunteun ayeuna (A) | ||||||||||||
1 | 1.3 | 1.26 | 1.23 | 1.19 | 1.15 | 1.11 | 1.05 | 1 | 0.96 | 0.93 | 0.88 | 0.83 |
2 | 2.6 | 2.52 | 2.46 | 2.38 | 2.28 | 2.2 | 2.08 | 2 | 1.92 | 1.86 | 1.76 | 1.66 |
3 | 3.9 | 3.78 | 3.69 | 3.57 | 3.42 | 3.3 | 3.12 | 3 | 2.88 | 2.79 | 2.64 | 2.49 |
4 | 5.2 | 5.04 | 4.92 | 4.76 | 4.56 | 4.4 | 4.16 | 4 | 3.84 | 3.76 | 3.52 | 3.32 |
6 | 7.8 | 7.56 | 7.38 | 7.14 | 6.84 | 6.6 | 6.24 | 6 | 5.76 | 5.64 | 5.28 | 4.98 |
10 | 13.2 | 12.7 | 12.5 | 12 | 11.5 | 11.1 | 10.6 | 10 | 9.6 | 9.3 | 8.9 | 8.4 |
13 | 17.16 | 16.51 | 16.25 | 15.6 | 14.95 | 14.43 | 13.78 | 13 | 12.48 | 12.09 | 11.57 | 10.92 |
16 | 21.12 | 20.48 | 20 | 19.2 | 18.4 | 17.76 | 16.96 | 16 | 15.36 | 14.88 | 14.24 | 13.44 |
20 | 26.4 | 25.6 | 25 | 24 | 23 | 22.2 | 21.2 | 20 | 19.2 | 18.6 | 17.8 | 16.8 |
25 | 33 | 32 | 31.25 | 30 | 28.75 | 27.75 | 26.5 | 25 | 24 | 23.25 | 22.25 | 21 |
32 | 42.56 | 41.28 | 40 | 38.72 | 37.12 | 35.52 | 33.93 | 32 | 30.72 | 29.76 | 28.16 | 26.88 |
40 | 53.2 | 51.2 | 50 | 48 | 46.4 | 44.8 | 42.4 | 40 | 38.4 | 37.2 | 35.6 | 33.6 |
50 | 67 | 65.5 | 63 | 60.5 | 58 | 56 | 53 | 50 | 48 | 46.5 | 44 | 41.5 |
63 | 83.79 | 81.9 | 80.01 | 76.86 | 73.71 | 70.56 | 66.78 | 63 | 60.48 | 58.9 | 55.44 | 52.29 |
Jenis tripping | Dipeunteun ayeuna (A) | Faktor koreksi ayeuna | Contona | ||
≤2000m | 2000-3000m | ≥3000m | |||
B, C, K | 1, 2, 3, 4, 6, 10, 13, 16, 20, 25 32, 40, 50, 63 | 1 | 0.9 | 0.8 | Dipeunteun ayeuna 10A produk nyaéta 0,9 × 10 = 9A sanggeus derating di 2500m |
Kapasitas wiring
Dipeunteun ayeuna Dina (A) | Wewengkon cross-sectional nominal konduktor tambaga (mm²) |
1~6 | 1 |
10 | 1.5 |
13, 16, 20 | 2.5 |
25 | 4 |
32 | 6 |
40,50 | 10 |
63 | 16 |
Dipeunteun ayeuna Dina (A) | Konsumsi kakuatan maksimum per tahap (W) |
1~10 | 2 |
13~32 | 3.5 |
40~63 | 5 |
The asesoris handap cocog pikeun runtuyan YCB8-63PV, nu bisa nyadiakeun fungsi kadali jauh tina circuit breaker, disconnection otomatis tina circuit sesar, indikasi status (megatkeun / nutup / sesar tripping).
a. Lebar total tina asesoris dirakit aya dina 54mm, urutan jeung kuantitas ti kénca ka katuhu: OF, SD (3max) + MX, MX + OF + MCB, SD ngan bisa ngumpul nepi ka 2 lembar ;
b. Dirakit jeung awak, euweuh parabot diperlukeun;
c. Sateuacan dipasang, pariksa naha parameter téknis produk nyumponan sarat pamakean, sareng ngajalankeun cecekelan pikeun muka sareng nutup sababaraha kali pikeun mariksa naha mékanismena tiasa dipercaya.
● kontak bantu OF
indikasi jauh tina status nutup / bubuka circuit breaker.
● Alarm kontak SD
Nalika sesar circuit breaker lalampahan, éta ngirimkeun kaluar sinyal, bareng jeung indikator beureum dina hareupeun alat.
● Shunt ngaleupaskeun MX
Nalika tegangan catu daya nyaéta 70% ~ 110% Ue, pemutus sirkuit kontrol jarak jauh saatos nampi sinyal.
● Minimum nyieun jeung megatkeun ayeuna: 5mA (DC24V)
● hirup Service: 6000 kali (frékuénsi operasi: 1s)
Modél | YCB8-63 OF | YCB8-63 SD | YCB8-63 MX |
Penampilan | |||
Jenis | |||
Jumlah kontak | 1NO+1NC | 1NO+1NC | / |
Tegangan kontrol (V AC) | 110-415 48 12-24 | ||
Tegangan kontrol (V DC) | 110-415 48 12-24 | ||
Gawé ayeuna kontak | AC-12 Ue/Ie: AC415/3A DC-12 Ue/Ie: DC125/2A | / | |
tegangan kontrol Shunt | Ue/Ie: AC: 220-415 / 0.5A AC / DC: 24-48/3 | ||
Lebar (mm) | 9 | 9 | 18 |
Kaayaan Lingkungan anu Larapkeun sareng Pamasangan | |||
Suhu neundeun (℃) | -40 ℃ ~ + 70 ℃ | ||
Kelembaban gudang | kalembaban relatif teu ngaleuwihan 95% lamun dina +25 ℃ | ||
Gelar panyalindungan | Tingkat 2 | ||
Gelar panyalindungan | IP20 | ||
lingkungan instalasi | Tempat tanpa geter sareng dampak anu signifikan | ||
Kategori instalasi | Golongan II, Golongan III | ||
Métode pamasangan | Pamasangan rel TH35-7.5 / DIN35 | ||
kapasitas wiring maksimum | 2,5 mm² | ||
torsi terminal | 1N·m |
OF / SD Outline jeung dimensi instalasi
MX + OF Outline jeung dimensi instalasi