YCM8-PV Photovoltaic DC MCCB
Features ● Ultra-wide breaking capacity: rated working voltage up to DC1500V and rated current up to 800A. Under DC1500V working conditions, Icu =Ics=20KA, ensuring reliable short-circuit protection. ● Small size: for frame currents up to 320A, the 2P rated working voltage can reach DC1000V, and for frame currents of 400A and above, the 2P rated working voltage can reach DC1500V. ● Ultra-long arc-extinguishing chamber: the arc-extinguishing chamber has been improved as a whole, with more arc-...YCF8-63PVS Photovoltaic DC Fuse
Selection YCF8 - 63 PVS DC1500 Model Shell frame Product type Rated Voltage Fuse 63 PVS:Photovoltaic DC sailboat DC1500V Technical data Model YCF8-63PVS Fuse size(mm) 10 ×85 14 ×85 Rated working voltage Ue(V) DC1500 Rated insulation voltage Ui(V) DC1500 Rated short-circuit breaking capacity (KA) 20 Operating level gPV Standard IEC60269-6, UL4248-19 Number of poles 1P Installation method TH-35 Din-rail installation Operating environment and installation Working...YCS8-S Photovoltaic DC Surge Protective Device
Features ● T2/T1+T2 surge protection has two types of protection, which can can meet Class I (10/350 μS waveform) and Class II (8/20 μS waveform) SPD test, and voltage protection level Up ≤ 1.5kV; ● Modular, large-capacity SPD, maximum discharge current Imax=40kA; ● Pluggable module; ● Based on zinc oxide technology, it has no power frequency aftercurrent and fast response speed, up to 25ns; ● The green window indicates normal, and the red indicates a defect, and the module needs to be replac...YCX8-IFS Solar Combiner Box
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-IFS 1/1 YCX8-IFS 6/2 Input/Output 1/1 6/2 Maximum voltage 1000VDC Maximum output current 32A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 219*200*100mm 381*200*100 Configuration (recommended) Photovoltaic isolation switch YCISC-32 2 DC1000 ...YCX8-T Waterproof Electrical Box
Selection YCX8 — T 858575 Corresponding overall dimensions(mm) Model Box type Dimension A B C D E Plastic distribution box T: Electrical box (transparent cover) 858575 85 85 75 74 74 111180 110 110 80 104 104 131390 130 130 90 124 124 131890 130 180 90 154 154 161690 160 160 90 154 154 162111 160 210 110 154 204 162112 160 210 120 154 204 182511 180 250 110 174 244 182511 180 250 120 174 244 202011 200 200 110 194 194 202012 200 200 120 194 194 212911...YCB1-125 MCB
Curve Specifications Type Standard IEC/EN 60947-2 IEC/EN 60898-1 Electrical features Rated current In A 63, 80, 100, 125 Poles P 1, 2, 3, 4 Rated voltage Ue V 230/400 Insulation voltage Ui V 500 Rated frequency Hz 50/60 Rated breaking capacity A 6000 Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1min kV 2.5 Pollution degree 3 Thermo-magnetic release characteristic 8-12In B, C,D Mechanical features Electrical life t ...