RT18 Low Voltage Fuse
Fuse Holder RT18 Type Assorted Fuse Ratedvoltage (V) RatedCurrent (A) Dimension (mm) A B C D E RT18-32(32X) 1P 10 ×38 380 32 82 78 35 63 18 RT18-32(32X) 2P 32 82 78 35 63 36 RT18-32(32X) 3P 32 82 78 35 63 54 RT18-63(63X) 1P 14 ×51 63 106 103 35 80 26 RT18-63(63X) 2P 63 106 103 35 80 52 RT18-63(63X) 3P 63 106 103 35 80 78 RT18L Type Assorted Fuse Number of Poles Rated voltage (V) Conventional heating current (A) Dimension (mm) A B C D E RT18L-63 14 ×51 1,2,3,4 690 6...YCX8 Series DC Combiner Box
Features ● Multiple solar photovoltaic arrays can be connected simultaneously, with a maximum of 6 circuits; ● Rated input current of each circuit is 15A (customizable as required); ● The output terminal is equipped with a photovoltaic DC high-voltage lightning protection module that can withstand a maximum lightning current of 40kA; ● High voltage circuit breaker is adopted, with DC rated working voltage up to DC1000, safe and reliable; ● The protection level reaches IP65, meeting the use re...YCRP Rapid Shutdown Switch
Features ● Shutdown when ambient temperature exceeds 85℃; ● Ultra-thin size perfectly matches the module; ● Flame retardant grade: UL94-V0; ● Protection grade: IP68; ● Meet UL standard and SUNSPEC protocol; ● PLC control optional; ● Hook design, convenient and simple installation, saving labor costs. Shutdown mode Selection YCRP — 15 P S — S Model Rated current Communication method DC input DC input Rapid shutdown device 15: 15A 21: 21A P: PLC W: Wifi S: Single D: Dual S: Screw type ...YCX8-DIS Door Clutch Combiner
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-DIS 1/1 15/32 Input/Output 1/1 Maximum voltage 600V 1000V Short circuit current per input (Isc) 15A-30A(Adjustable) Maximum output current 16A 25A Shell frame Material Polycarbonate Protection degree IP66 Impact resistance IK10 Dimension(width ×height ×depth) 160*210*110 Input cable gland MC4/PG09,2.5~16mm Out...YCB1-125 MCB
Curve Specifications Type Standard IEC/EN 60947-2 IEC/EN 60898-1 Electrical features Rated current In A 63, 80, 100, 125 Poles P 1, 2, 3, 4 Rated voltage Ue V 230/400 Insulation voltage Ui V 500 Rated frequency Hz 50/60 Rated breaking capacity A 6000 Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1min kV 2.5 Pollution degree 3 Thermo-magnetic release characteristic 8-12In B, C,D Mechanical features Electrical life t ...YCX8-IFS Solar Combiner Box
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-IFS 1/1 YCX8-IFS 6/2 Input/Output 1/1 6/2 Maximum voltage 1000VDC Maximum output current 32A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 219*200*100mm 381*200*100 Configuration (recommended) Photovoltaic isolation switch YCISC-32 2 DC1000 ...