Product Overview
Product Details
Data Download
Related Products
General
The YCF8-32 PV series fuse is designed with a rated operating voltage of DC1500V and a current rating of 80A, making it suitable for use in solar photovoltaic DC combiner boxes. Its primary function is to interrupt line overload and short-circuit currents that may arise due to current feedback from solar panel components and inverters, providing essential protection to the photovoltaic components. This fuse is integral to preventing damage in solar power systems by isolating and protecting individual circuits, thereby enhancing the reliability and safety of the entire photovoltaic setup.
Standard: IEC60269, UL4248-19.
Conatct Us
The fuse base is made of a plastic pressed shell with contacts and fuse-carrying parts, which are riveted and connected, and can be used as the supporting part of the fuse link of corresponding size. This series of fuses has the characteristics of small size, convenient installation, safe use and beautiful appearance.
YCF8 | - | 32 | X | PV | DC1500 |
Model | Shell frame | Functions | Product type | Rated Voltage | |
Fuse | 32: 1~32A | /:standard X: With display H: High base | PV: Photovoltaic/ direct-current | DC1000V | |
63: 15~40A | /:non | DC1000V | |||
125: 40~80A | DC1500V |
Fuse holder | Assembly fuse |
YCF8-32 | YCF8-1038 |
YCF8-63 | YCF8-1451 |
YCF8-125 | YCF8-2258 |
Model | YCF8-32PV | YCF8-63PV | YCF8-125PV |
Specifications | /:standard X: With display H: High base | /:standard | /:standard |
Fuse size(mm) | 10 ×38 | 14 ×51 | 22 ×58 |
Rated working voltage Ue(V) | DC1000 | DC1500 | |
Rated insulation voltage Ui(V) | DC1500 | ||
Use category | gPV | ||
Standard | IEC60269-6, UL4248-19 | ||
Number of poles | 1P | ||
Operating environment and installation | |||
Working temperature | -40℃≤X≤+90℃ | ||
Altitude | ≤2000m | ||
Humidity | When the maximum temperature is+40℃, the relative humidity of the air shall not exceed 50%, and higher humidity can be allowed at lower temperatures,For example+ 90% at 25℃. Special measures shall be taken for occasional condensation due to temperature changes; | ||
Installation environment | In a place where there is no explosive medium and the medium is not enough to corrode metal and damage insulation gas and conductive dust. | ||
Pollution degree | Level 3 | ||
Installation category | III | ||
Installation method | TH-35 Din-rail installation |
The variable cross-section melt made of pure silver sheet (or silver wire winding) is soldered with low-temperature tin and packaged in a fusion tube made of high- strength porcelain. The fusion tube is filled with chemically treated and specially processed Process-treated high-purity quartz sand is used as the arc-extinguishing medium, and the two ends of the melt are firmly electrically connected with the contacts by electric welding.
YCF8 | - | 1038 | 25A | DC1500 |
Model | Size | Rated current | Rated voltage | |
Fuse | 1038: 10×38 | 1,2,3,4,5,6,8,10,15, 16,20,25,30,32 | DC1000V | |
1451: 14×51 | 15,16,20,25,30, 32,40,50 | DC1000V DC1500V | ||
2258: 22×58 | 40,50,63,80 |
Model | YCF8-1038 | YCF8-1451 | YCF8-2258 |
Rated current In(A) | 1,2,3,4,5,6,8,10,12,15, 20,25,30,32 | 15,20,25,30,32,40,50 | 40,50,63,80 |
Specifications | / X: With display H: High base | / | / |
Fuse size(mm) | 10×38 | 14×51 | 22×58 |
Rated working voltage Ue(V) | DC1000 | DC1000,DC1500 | |
Rated short-circuit breaking capacity (KA) | 20 | ||
Time constant(ms) | 1-3ms | ||
Operating level | gPV | ||
Standards | IEC60269-6, UL248-19 |
The agreed time and current of the fuse “gPV”
Rated current of the fuse “gPV” (A) | Agreed time (h) | Agreed current | |
Inf | If | ||
In ≤63 | 1 | 1.13In | 1.45In |
632 | | ||
1603 | | ||
In>400 | 4 |
Model | Rated current | Joule integral I²T(A²S) | |
(A) | Pre-arcing | Total | |
YCF8-1038 | 1 | 0.15 | 0.4 |
2 | 1.2 | 3.3 | |
3 | 3.9 | 11 | |
4 | 10 | 27 | |
5 | 18 | 48 | |
6 | 31 | 89 | |
8 | 3.1 | 31 | |
10 | 7.2 | 68 | |
12 | 16 | 136 | |
15 | 24 | 215 | |
16 | 28 | 255 | |
20 | 38 | 392 | |
25 | 71 | 508 | |
30 | 102 | 821 | |
32 | 176 | 976 | |
YCF8-1451 | 15 | 330 | 275 |
20 | 220 | 578 | |
25 | 275 | 956 | |
30 | 380 | 1160 | |
32 | 405 | 1830 | |
40 | 600 | 2430 | |
50 | 850 | 3050 | |
YCF8-2258 | 40 | 750 | 3450 |
50 | 1020 | 5050 | |
63 | |||
80 |
Base
Link