YCB2000PV Series DC Variable Frequency Drive

Solar pumping system
The YCB2000PV solar pumping system serves to provide water in remote applicarions where electrical grid power is either unreliable or unavailable. The system pumps water using a high-voltage DC power source such as aphotovoltaic array of solar panels. Since the sun is only available during certain hours of a day and only in good weather conditions, the water is generally pumped into a storage pool or tank for furher usage. And water sources are those natural or special such as river, lake, well or waterway, etc.
Solar pumping system is constituted by solar module array, combine r box, liquid level switch, solar pump erc. It aims at providing solutions for the region that suffers water shortage, no power supply or uncertain power supply.

Conatct Us

Product Details

product-description1

General

In order to satisfy the demands of various pumping applications, YCB2000PV solar pump controller adopts Max Power Point Tracking and proven motor drive technology to maximize output from solar modules. It supports both single phase or three-phase AC input such as a generator or inverter from battery. The controller provides fault detection, motor soft start, and speed control. YCB2000PV controller is designed to proceed these features with the plug and play, ease of installation.

Selection

YCB2000PV T 5D5 G
Model Output voltage Adaptive power Load type
Photovoltaic Inverter S: Single phase AC220V

T: Three phase AC380V

0D75:0.75KW
1D5:1.5KW
2D2:2.2KW
4D0:4.0KW
5D5:5.5KW
7D5:7.5KW
011:11KW
015:15KW
….
110:110KW
G: Constant torque

 

   Flexibility

Compatible with IEC standard three-    phase asynchronous induction motors Compatible weth popular PV arrays

Grid supply option

 

Remote monitoring

Standard Rs485 interface equipped for each solar pump controller

Optional GPRS/Wi-Fi/ Erhernet Rj45 modules for remote access

Spots value of solar pump parameters monitoring available from anywhere     History of solar pump parameters and  events lookup support

Android/iOS monitoring APP support

 

Cost effectiveness

Plug-and-play system design

Embedded motor protection and pump functions

Battery-free for most applications Effortless maintenance

 

Reliability

10-year market proven experience of leading motor and pump drive technology

Soft start feature to prevent water hammer and increase system life

Built-in overvoltage ,overload ,overheat and dry- run protection

 

Smartness

Self-adaptive maximum power point

tracking technology up to 99% efficiency Automatic regulation of pump flow

Self-adaptation to the motor used in the installation

Protection

Surge protection

Overvoltage protection   Undervoltage protection Locked pump protection Open circuit protection    Short circuit protection    Overheat protection

Dry run protection

 

General data

Ambient Temperature Tange:  -20 ° C~60 ° C ,

〉45 ° C , Derating as required

Cooling Method :Fan Cooling Ambient Humidity:≤95% RH

product-description2

Technical data

Model YCB2000PV-S0D7G YCB2000PV-S1D5G YCB2000PV-S2D2G YCB2000PV-T2D2G YCB2000PV-T4D0G
Input data
PV Source
Max input voltage(Voc)[V] 400 750
Min input voltage, at mpp[V] 180 350
Recommended voltage,at mpp 280VDC~360VDC 500VDC~600VDC
Recommended amps input,at mpp[A] 4.7 7.3 10.4 6.2 11.3
Recommended max power at mpp[kW] 1.5 3 4.4 11 15
Output data
Input voltage 220/230/240VAV(±15%),Single Phase 380VAV(±15%),Three Phase
Max amps(RMS)[A] 8.2 14 23 5.8 10
Power and va capability [kVA] 2 3.1 5.1 5 6.6
Rated output power[kW] 0.75 1.5 2.2 2.2 4
Rated output voltage 220/230/240VAC,Single Phase 380VAC,Three Phase
Max amps(RMS)[A] 4.5 7 10 5 9
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 1.0-1.2 2.0-2.4 3.0-3.5 3.0-3.5 5.2-6.4
Solar panel connection 250W×5P×30V 250W×10P×30V 250W×14P×30V 250W×20P×30V 250W×22P×30V
Applicable pump (kW) 0.37-0.55 0.75-1.1 1.5 1.5 2.2-3
Pump motor voltage(V) 3 phase 220 3 phase 220 3 phase 220 3 phase 380 3 phase 380

Technical data

Model YCB2000PV-T5D5G YCB2000PV-T7D5G YCB2000PV-T011G YCB2000PV-T015G YCB2000PV-T018G
Input data
PV source
Max input voltage(Voc)[V] 750
Min input voltage, at mpp[V] 350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A] 16.2 21.2 31.2 39.6 46.8
Recommended max power at mpp[kW] 22 30 22 30 37
Alternate AC generator
Input voltage 380VAV(±15%) ,Three Phase
Max amps(RMS)[A] 15 20 26 35 46
Power and va capability [kVA] 9 13 17 23 25
Output data
Rated output power[kW] 5.5 7.5 11 15 18.5
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 13 17 25 32 37
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 7.2-8.8 9.8-12 14.3-17.6 19.5-24 24-29.6
Solar panel connection 250W×40P×30V
20 series 2 parallel
250W×48P×30V 24 series 2 parallel 250W×60P×30V 20 series 3 parallel 250W×84P×30V 21 series 4 parallel 250W×100P×30V 20 series 5 parallel
Applicable pump (kW) 3.7-4 4.5-5.5 7.5-9.2 11-13 15
Pump motor voltage(V) 3 phase 380 3 phase 380 3 phase 380 3 phase 380 3 phase 380

Technical data

Model YCB2000PV-T022G YCB2000PV-T030G YCB2000PV-T037G YCB2000PV-T045G
Input data
PV source
Max input voltage(Voc)[V] 750
Min input voltage, at mpp[V] 350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A] 56 74 94 113
Recommended max power at mpp[kW] 44 60 74 90
Alternate AC generator
Input voltage 380VAV(±15%) ,Three Phase
Max amps(RMS)[A] 62 76 76 90
Power and va capability [kVA] 30 41 50 59.2
Output data
Rated output power[kW] 22 30 37 45
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 45 60 75 90
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 28.6-35.2 39-48 48.1-59.2 58.5-72
Solar panel connection 250W×120P×30V
20 series 6 parallel
250W×200P×30V
20 series 10 parallel
250W×240P×30V
22 series 12 parallel
250W×84P×30V
21 series 4 parallel
Applicable pump (kW) 18.5 22-26 30 37-40
Pump motor voltage(V) 3 phase 380 3 phase 380 3 phase 380 3 phase 380

Technical data

Model YCB2000PV-T055G YCB2000PV-T075G YCB2000PV-T090G YCB2000PV-T110G
Input data
PV source
Max input voltage(Voc)[V] 750
Min input voltage, at mpp[V] 350
Recommended voltage,at mpp 500VDC~600VDC
Recommended amps input,at mpp[A] 105 140 160 210
Recommended max power at mpp[kW] 55 75 90 110
Alternate AC generator
Input voltage 380VAV(±15%) ,Three Phase
Max amps(RMS)[A] 113 157 180 214
Power and va capability [kVA] 85 114 134 160
Output data
Rated output power[kW] 55 75 93 110
Rated output voltage 380VAC,Three Phase
Max amps(RMS)[A] 112 150 176 210
Output frequency 0-50Hz/60Hz
Pump system configuration parameters
Recommended solar panel power(KW) 53-57 73-80 87-95 98-115
Solar panel connection 400W*147P*30V  21series 7 parallel 400W*200P*30V
20 series 10 parallel
400W*240P*30V
20 series 12 parallel
400W*280P*30V
20 series 4 parallel
Applicable pump (kW) 55 75 90 110
Pump motor voltage(V) 3PH 380V

External dimension

                                           Size
Model
W(mm) H(mm) D(mm) A(mm) B(mm) Mounting Aperture
YCB2000PV-S0D7G 125 185 163 115 175 4
YCB2000PV-S1D5G
YCB2000PV-S2D2G
YCB2000PV-T0D7G
YCB2000PV-T1D5G
YCB2000PV-T2D2G
YCB2000PV-T3D0G 150 246 179 136 230 4
YCB2000PV-T4D0G
YCB2000PV-T5D5G
YCB2000PV-T7D5G
YCB2000PV-T011G 218 320 218 201 306 5
YCB2000PV-T015G
YCB2000PV-T018G
YCB2000PV-T022G 235 420 210 150 404 5
YCB2000PV-T030G 270 460 220 195 433 6
YCB2000PV-T037G
YCB2000PV-T045G 320 565 275 240 537 6
YCB2000PV-T055G
YCB2000PV-T075G 380 670 272 274 640 8
YCB2000PV-T090G
YCB2000PV-T110G

Overall and mounting dimensions(mm)

product-description3

product-description4

Scenic spot of daocheng yading, shangri-la:

System installed in Scenic Spot of Daocheng Yading, Shangri-la to cloth barren mountains with greenery scene. 3pcs 37kW solar pumps, 3PCS YCB2000PV-T037G Solar Pump Controllers.
System capacity: 160KW
Panels: 245W
Altitude: 3400M
Pumping3height: 250M
Flow: 69M / H

product-description5