Product Overview
Product Details
Data Download
Related Products
Solar pumping system
The YCB2000PV solar pumping system serves to provide water in remote applicarions where electrical grid power is either unreliable or unavailable. The system pumps water using a high-voltage DC power source such as aphotovoltaic array of solar panels. Since the sun is only available during certain hours of a day and only in good weather conditions, the water is generally pumped into a storage pool or tank for furher usage. And water sources are those natural or special such as river, lake, well or waterway, etc.
Solar pumping system is constituted by solar module array, combine r box, liquid level switch, solar pump erc. It aims at providing solutions for the region that suffers water shortage, no power supply or uncertain power supply.
Conatct Us
In order to satisfy the demands of various pumping applications, YCB2000PV solar pump controller adopts Max Power Point Tracking and proven motor drive technology to maximize output from solar modules. It supports both single phase or three-phase AC input such as a generator or inverter from battery. The controller provides fault detection, motor soft start, and speed control. YCB2000PV controller is designed to proceed these features with the plug and play, ease of installation.
YCB2000PV | — | T | 5D5 | G |
Model | Output voltage | Adaptive power | Load type | |
Photovoltaic Inverter | S: Single phase AC220V T: Three phase AC380V | 0D75:0.75KW 1D5:1.5KW 2D2:2.2KW 4D0:4.0KW 5D5:5.5KW 7D5:7.5KW 011:11KW 015:15KW …. 110:110KW | G: Constant torque |
Flexibility Compatible with IEC standard three- phase asynchronous induction motors Compatible weth popular PV arrays Grid supply option
Remote monitoring Standard Rs485 interface equipped for each solar pump controller Optional GPRS/Wi-Fi/ Erhernet Rj45 modules for remote access Spots value of solar pump parameters monitoring available from anywhere History of solar pump parameters and events lookup support Android/iOS monitoring APP support
Cost effectiveness Plug-and-play system design Embedded motor protection and pump functions Battery-free for most applications Effortless maintenance
Reliability 10-year market proven experience of leading motor and pump drive technology Soft start feature to prevent water hammer and increase system life Built-in overvoltage ,overload ,overheat and dry- run protection
Smartness Self-adaptive maximum power point tracking technology up to 99% efficiency Automatic regulation of pump flow Self-adaptation to the motor used in the installation | Protection Surge protection Overvoltage protection Undervoltage protection Locked pump protection Open circuit protection Short circuit protection Overheat protection Dry run protection
General data Ambient Temperature Tange: -20 ° C~60 ° C , 〉45 ° C , Derating as required Cooling Method :Fan Cooling Ambient Humidity:≤95% RH |
Model | YCB2000PV-S0D7G | YCB2000PV-S1D5G | YCB2000PV-S2D2G | YCB2000PV-T2D2G | YCB2000PV-T4D0G |
Input data | |||||
PV Source | |||||
Max input voltage(Voc)[V] | 400 | 750 | |||
Min input voltage, at mpp[V] | 180 | 350 | |||
Recommended voltage,at mpp | 280VDC~360VDC | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 4.7 | 7.3 | 10.4 | 6.2 | 11.3 |
Recommended max power at mpp[kW] | 1.5 | 3 | 4.4 | 11 | 15 |
Output data | |||||
Input voltage | 220/230/240VAV(±15%),Single Phase | 380VAV(±15%),Three Phase | |||
Max amps(RMS)[A] | 8.2 | 14 | 23 | 5.8 | 10 |
Power and va capability [kVA] | 2 | 3.1 | 5.1 | 5 | 6.6 |
Rated output power[kW] | 0.75 | 1.5 | 2.2 | 2.2 | 4 |
Rated output voltage | 220/230/240VAC,Single Phase | 380VAC,Three Phase | |||
Max amps(RMS)[A] | 4.5 | 7 | 10 | 5 | 9 |
Output frequency | 0-50Hz/60Hz | ||||
Pump system configuration parameters | |||||
Recommended solar panel power(KW) | 1.0-1.2 | 2.0-2.4 | 3.0-3.5 | 3.0-3.5 | 5.2-6.4 |
Solar panel connection | 250W×5P×30V | 250W×10P×30V | 250W×14P×30V | 250W×20P×30V | 250W×22P×30V |
Applicable pump (kW) | 0.37-0.55 | 0.75-1.1 | 1.5 | 1.5 | 2.2-3 |
Pump motor voltage(V) | 3 phase 220 | 3 phase 220 | 3 phase 220 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T5D5G | YCB2000PV-T7D5G | YCB2000PV-T011G | YCB2000PV-T015G | YCB2000PV-T018G |
Input data | |||||
PV source | |||||
Max input voltage(Voc)[V] | 750 | ||||
Min input voltage, at mpp[V] | 350 | ||||
Recommended voltage,at mpp | 500VDC~600VDC | ||||
Recommended amps input,at mpp[A] | 16.2 | 21.2 | 31.2 | 39.6 | 46.8 |
Recommended max power at mpp[kW] | 22 | 30 | 22 | 30 | 37 |
Alternate AC generator | |||||
Input voltage | 380VAV(±15%) ,Three Phase | ||||
Max amps(RMS)[A] | 15 | 20 | 26 | 35 | 46 |
Power and va capability [kVA] | 9 | 13 | 17 | 23 | 25 |
Output data | |||||
Rated output power[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 |
Rated output voltage | 380VAC,Three Phase | ||||
Max amps(RMS)[A] | 13 | 17 | 25 | 32 | 37 |
Output frequency | 0-50Hz/60Hz | ||||
Pump system configuration parameters | |||||
Recommended solar panel power(KW) | 7.2-8.8 | 9.8-12 | 14.3-17.6 | 19.5-24 | 24-29.6 |
Solar panel connection | 250W×40P×30V 20 series 2 parallel | 250W×48P×30V 24 series 2 parallel | 250W×60P×30V 20 series 3 parallel | 250W×84P×30V 21 series 4 parallel | 250W×100P×30V 20 series 5 parallel |
Applicable pump (kW) | 3.7-4 | 4.5-5.5 | 7.5-9.2 | 11-13 | 15 |
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T022G | YCB2000PV-T030G | YCB2000PV-T037G | YCB2000PV-T045G |
Input data | ||||
PV source | ||||
Max input voltage(Voc)[V] | 750 | |||
Min input voltage, at mpp[V] | 350 | |||
Recommended voltage,at mpp | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 56 | 74 | 94 | 113 |
Recommended max power at mpp[kW] | 44 | 60 | 74 | 90 |
Alternate AC generator | ||||
Input voltage | 380VAV(±15%) ,Three Phase | |||
Max amps(RMS)[A] | 62 | 76 | 76 | 90 |
Power and va capability [kVA] | 30 | 41 | 50 | 59.2 |
Output data | ||||
Rated output power[kW] | 22 | 30 | 37 | 45 |
Rated output voltage | 380VAC,Three Phase | |||
Max amps(RMS)[A] | 45 | 60 | 75 | 90 |
Output frequency | 0-50Hz/60Hz | |||
Pump system configuration parameters | ||||
Recommended solar panel power(KW) | 28.6-35.2 | 39-48 | 48.1-59.2 | 58.5-72 |
Solar panel connection | 250W×120P×30V 20 series 6 parallel | 250W×200P×30V 20 series 10 parallel | 250W×240P×30V 22 series 12 parallel | 250W×84P×30V 21 series 4 parallel |
Applicable pump (kW) | 18.5 | 22-26 | 30 | 37-40 |
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T055G | YCB2000PV-T075G | YCB2000PV-T090G | YCB2000PV-T110G |
Input data | ||||
PV source | ||||
Max input voltage(Voc)[V] | 750 | |||
Min input voltage, at mpp[V] | 350 | |||
Recommended voltage,at mpp | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 105 | 140 | 160 | 210 |
Recommended max power at mpp[kW] | 55 | 75 | 90 | 110 |
Alternate AC generator | ||||
Input voltage | 380VAV(±15%) ,Three Phase | |||
Max amps(RMS)[A] | 113 | 157 | 180 | 214 |
Power and va capability [kVA] | 85 | 114 | 134 | 160 |
Output data | ||||
Rated output power[kW] | 55 | 75 | 93 | 110 |
Rated output voltage | 380VAC,Three Phase | |||
Max amps(RMS)[A] | 112 | 150 | 176 | 210 |
Output frequency | 0-50Hz/60Hz | |||
Pump system configuration parameters | ||||
Recommended solar panel power(KW) | 53-57 | 73-80 | 87-95 | 98-115 |
Solar panel connection | 400W*147P*30V 21series 7 parallel | 400W*200P*30V 20 series 10 parallel | 400W*240P*30V 20 series 12 parallel | 400W*280P*30V 20 series 4 parallel |
Applicable pump (kW) | 55 | 75 | 90 | 110 |
Pump motor voltage(V) | 3PH 380V |
Size Model | W(mm) | H(mm) | D(mm) | A(mm) | B(mm) | Mounting Aperture |
YCB2000PV-S0D7G | 125 | 185 | 163 | 115 | 175 | 4 |
YCB2000PV-S1D5G | ||||||
YCB2000PV-S2D2G | ||||||
YCB2000PV-T0D7G | ||||||
YCB2000PV-T1D5G | ||||||
YCB2000PV-T2D2G | ||||||
YCB2000PV-T3D0G | 150 | 246 | 179 | 136 | 230 | 4 |
YCB2000PV-T4D0G | ||||||
YCB2000PV-T5D5G | ||||||
YCB2000PV-T7D5G | ||||||
YCB2000PV-T011G | 218 | 320 | 218 | 201 | 306 | 5 |
YCB2000PV-T015G | ||||||
YCB2000PV-T018G | ||||||
YCB2000PV-T022G | 235 | 420 | 210 | 150 | 404 | 5 |
YCB2000PV-T030G | 270 | 460 | 220 | 195 | 433 | 6 |
YCB2000PV-T037G | ||||||
YCB2000PV-T045G | 320 | 565 | 275 | 240 | 537 | 6 |
YCB2000PV-T055G | ||||||
YCB2000PV-T075G | 380 | 670 | 272 | 274 | 640 | 8 |
YCB2000PV-T090G | ||||||
YCB2000PV-T110G |
System installed in Scenic Spot of Daocheng Yading, Shangri-la to cloth barren mountains with greenery scene. 3pcs 37kW solar pumps, 3PCS YCB2000PV-T037G Solar Pump Controllers.
System capacity: 160KW
Panels: 245W
Altitude: 3400M
Pumping3height: 250M
Flow: 69M / H